4 research outputs found

    Synthesis and characterisation of PEG-peptide surfaces for proteolytic enzyme detection

    Get PDF
    Peptide surfaces were obtained by the covalent immobilisation of fluorescently labelled pentapeptides carboxyfluorescein–glycine–arginine–methionine–leucine–glycine, either directly or through a poly(ethylene glycol) (PEG) linker on modified silicon wafers. Each step during the preparation of the peptide surfaces was confirmed by several surface characterisation techniques. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy were used to determine the surface composition, the wafers philicity was measured by contact angle and atomic force microscopy was used to investigate the surface morphology. Exposure of the peptide surfaces to trypsin resulted in the release of a fluorescently labelled peptide product, which allowed the kinetics of the enzymatic reaction to be followed with the aid of fluorescence spectroscopy. The electrospray ionisation mass spectrometry analysis of the post-digestion solution confirmed that the pentapeptides attached to the solid support undergo specific trypsin hydrolysis at the C-terminus of the arginine residues. Detailed surface analyses before and after the enzyme action was performed using ToF-SIMS. Because of the limited accessibility of the short peptide directly attached to the surface, a quantitative yield of enzymatic hydrolysis was observed only in case when the peptide was bound through the PEG linker. The insertion of the PEG linker increased the number of immobilised peptides and the rate of enzymatic digestion which consequently improved the quality of the enzyme assays. The described approach may be used for different peptide sequences designed for other proteases. Figure Monitoring of trypsin hydrolysis on PEG-peptide surfac

    Relevance of the poly(ethylene glycol) linkers in peptide surfaces for proteases assays

    No full text
    Poly(ethylene glycol)s (PEGs) with different lengths were used as linkers during the preparation of peptide surfaces for protease detection. In the first approach, the PEG monolayers were prepared using a "grafting to" method on 3-aminopropyltrietoxysilane (APTES)-modified silicon wafers. Protected peptides with a fluorescent marker were synthesized by Fmoc solid phase synthesis. The protected peptide structures enabled their site-specific immobilization onto the PEG surfaces. Alternatively, the PEG-peptide surface was obtained by immobilizing a PEG-peptide conjugate directly onto the modified silicon wafer. The surfaces (composition, grafting density, hydrophilicity, and roughness) were characterized by time-of-flight-secondary ion mass spectrometry (ToF-SIMS), X-ray photoelectron spectroscopy (XPS), contact angle (CA), and atomic force microscopy (AFM). Introducing the PEG linker between the peptide and surface increased their resistance toward nonspecific protein adsorption. The peptide surfaces were examined as analytical platforms to study the action of trypsin as a representative protease. The products of the enzymatic hydrolysis were analyzed by fluorescence spectroscopy, electrospray ionization–mass spectrometry (ESI-MS), and ToF-SIMS. Conclusions about the optimal length of the PEG linker for the analytical application of PEG-peptide surfaces were drawn. This work demonstrates an effective synthetic procedure to obtain PEG-peptide surfaces as attractive platforms for the development of peptide microarrays

    Relevance of the Poly(ethylene glycol) Linkers in Peptide Surfaces for Proteases Assays

    No full text
    Poly­(ethylene glycol)­s (PEGs) with different lengths were used as linkers during the preparation of peptide surfaces for protease detection. In the first approach, the PEG monolayers were prepared using a “grafting to” method on 3-aminopropyltrietoxysilane (APTES)-modified silicon wafers. Protected peptides with a fluorescent marker were synthesized by Fmoc solid phase synthesis. The protected peptide structures enabled their site-specific immobilization onto the PEG surfaces. Alternatively, the PEG-peptide surface was obtained by immobilizing a PEG-peptide conjugate directly onto the modified silicon wafer. The surfaces (composition, grafting density, hydrophilicity, and roughness) were characterized by time-of-flight-secondary ion mass spectrometry (ToF-SIMS), X-ray photoelectron spectroscopy (XPS), contact angle (CA), and atomic force microscopy (AFM). Introducing the PEG linker between the peptide and surface increased their resistance toward nonspecific protein adsorption. The peptide surfaces were examined as analytical platforms to study the action of trypsin as a representative protease. The products of the enzymatic hydrolysis were analyzed by fluorescence spectroscopy, electrospray ionization–mass spectrometry (ESI-MS), and ToF-SIMS. Conclusions about the optimal length of the PEG linker for the analytical application of PEG-peptide surfaces were drawn. This work demonstrates an effective synthetic procedure to obtain PEG-peptide surfaces as attractive platforms for the development of peptide microarrays
    corecore